Bidirectional Flow Ventilation system
1. Surface spray treatment (color can be customized) or galvanized sheet color;
2. High-end heat recovery, imported heat exchange materials (Japan Prince), mildew, antibacterial, fire retardant;
3. Optional sensor, WiFi connection (doodle), LCD controller;
4. H11 or above HEPA filter is optional for better purification effect;
5.10 wind speed;
6. Standard EC fan
1-Features:Whole house purification;humanized noise cancellation;full heat exchange technology;in addition to effective bacterium;multiple filtering;three wind speed.
2-Enjoy the whole house in one machine;take a breath in silence
3-function:intelligent light;efficient anion;PM2.5 digital display;smart touch;filter change reminder;timing function
4-Parameter:
Model:HESQ-150DH-HB
Air volume(m3/h) | Overall dimension*No tuyere(mm) | Tuyere diameter(mm) | Power(W) | Noise value(dB) | Type |
150 | 680*530*220 | 146 | 80 | 38 | Bidirectional heat exchange |
Model:HESQ-250DH-HB
Air volume(m3/h) | Overall dimension*No tuyere(mm) | Tuyere diameter(mm) | Power(W) | Noise value(dB) | Type |
250 | 700*560*220 | 146 | 120 | 41 | Bidirectional heat exchange |
Model:HESQ-250DH-HB
Air volume(m3/h) | Overall dimension*No tuyere(mm) | Tuyere diameter(mm) | Power(W) | Noise value(dB) | Type |
350 | 800*650*220 | 146 | 160 | 45 | Bidirectional heat exchange |
The Ventilation System is based on the use of special equipment to send fresh air to the room on one side of a closed room, and then discharge from the other side to the outside by special equipment, forming a “fresh air flow field” indoors to meet the needs of indoor fresh air ventilation.
The two-way flow Ventilation System is a central mechanical air supply and exhaust system based on the three principles of mechanical ventilation system, and it is an effective supplement to the one-way flow Ventilation System. In the design of the two-way flow system, the positions of the exhaust air host and the indoor air outlet are basically the same as the unidirectional flow distribution. The difference is that the fresh air in the two-way flow system is supplied by the fresh air host. The fresh air main unit is connected to the indoor air distributor through a pipe, and the fresh air main unit continuously sends outdoor fresh air into the room through the pipe to meet people’s daily needs of fresh and quality air. Both the exhaust outlet and the fresh air outlet are equipped with air volume control valves, which can realize indoor ventilation through the power exhaust and delivery of the main engine.